TY - JOUR
T1 - Association of cardiac implantable electronic devices with survival in bifascicular block and prolonged PR interval on electrocardiogram
AU - Moulki, Naeem
AU - Kealhofer, Jessica V.
AU - Benditt, David G.
AU - Gravely, Amy
AU - Vakil, Kairav
AU - Garcia, Santiago
AU - Adabag, Selcuk
PY - 2018/8/1
Y1 - 2018/8/1
N2 - Purpose: Bifascicular block and prolonged PR interval on the electrocardiogram (ECG) have been associated with complete heart block and sudden cardiac death. We sought to determine if cardiac implantable electronic devices (CIED) improve survival in these patients. Methods: We assessed survival in relation to CIED status among 636 consecutive patients with bifascicular block and prolonged PR interval on the ECG. In survival analyses, CIED was considered as a time-varying covariate. Results: Average age was 76 ± 9 years, and 99% of the patients were men. A total of 167 (26%) underwent CIED (127 pacemaker only) implantation at baseline (n = 23) or during follow-up (n = 144). During 5.4 ± 3.8 years of follow-up, 83 (13%) patients developed complete or high-degree atrioventricular block and 375 (59%) died. Patients with a CIED had a longer survival compared to those without a CIED in the traditional, static analysis (log-rank p < 0.0001) but not when CIED was considered as a time-varying covariate (log-rank p = 0.76). In the multivariable model, patients with a CIED had a 34% lower risk of death (hazard ratio 0.66, 95% confidence interval 0.52–0.83; p = 0.001) than those without CIED in the traditional analysis but not in the time-varying covariate analysis (hazard ratio 1.05, 95% confidence interval 0.79–1.38; p = 0.76). Results did not change in the subgroup with a pacemaker only. Conclusions: Bifascicular block and prolonged PR interval on ECG are associated with a high incidence of complete atrioventricular block and mortality. However, CIED implantation does not have a significant influence on survival when time-varying nature of CIED implantation is considered.
AB - Purpose: Bifascicular block and prolonged PR interval on the electrocardiogram (ECG) have been associated with complete heart block and sudden cardiac death. We sought to determine if cardiac implantable electronic devices (CIED) improve survival in these patients. Methods: We assessed survival in relation to CIED status among 636 consecutive patients with bifascicular block and prolonged PR interval on the ECG. In survival analyses, CIED was considered as a time-varying covariate. Results: Average age was 76 ± 9 years, and 99% of the patients were men. A total of 167 (26%) underwent CIED (127 pacemaker only) implantation at baseline (n = 23) or during follow-up (n = 144). During 5.4 ± 3.8 years of follow-up, 83 (13%) patients developed complete or high-degree atrioventricular block and 375 (59%) died. Patients with a CIED had a longer survival compared to those without a CIED in the traditional, static analysis (log-rank p < 0.0001) but not when CIED was considered as a time-varying covariate (log-rank p = 0.76). In the multivariable model, patients with a CIED had a 34% lower risk of death (hazard ratio 0.66, 95% confidence interval 0.52–0.83; p = 0.001) than those without CIED in the traditional analysis but not in the time-varying covariate analysis (hazard ratio 1.05, 95% confidence interval 0.79–1.38; p = 0.76). Results did not change in the subgroup with a pacemaker only. Conclusions: Bifascicular block and prolonged PR interval on ECG are associated with a high incidence of complete atrioventricular block and mortality. However, CIED implantation does not have a significant influence on survival when time-varying nature of CIED implantation is considered.
KW - Atrioventricular block
KW - Bifascicular block
KW - Cardiac implantable electronic device
KW - Pacemaker
KW - Survival
UR - http://www.scopus.com/inward/record.url?scp=85048587253&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85048587253&partnerID=8YFLogxK
U2 - 10.1007/s10840-018-0389-0
DO - 10.1007/s10840-018-0389-0
M3 - Article
C2 - 29907894
AN - SCOPUS:85048587253
VL - 52
SP - 335
EP - 341
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
SN - 1383-875X
IS - 3
ER -