Automated Flow Cytometry for Acquisition of Time-Dependent Population Data

Nicholas R. Abu-Absi, Abdelqader Zamamiri, James Kacmar, Steven J. Balogh, Friedrich Srienc

Research output: Contribution to journalArticlepeer-review

56 Scopus citations

Abstract

Background: The implementation of flow cytometry in many experimental settings can be limited by the extensive amount of sample handling and preparation required for analysis. We describe a system that automatically performs sample handling and flow cytometric analysis, thus allowing one to construct detailed pictures of changes in cell population distributions as a function of time. Methods: Cell samples from bioreactors were loaded into a microchamber designed to perform all sample preparation steps including washing, fixation, staining, and dilution. The sample was then transported into a sample loop of known volume from which it was injected into the flow cell for determination of cell counts and measurement of scattering and fluorescence parameters. The apparatus was fully automated and controlled with a personal computer equipped with a data acquisition card. An inexpensive mechanism that continuously replenished the sheath fluid was implemented to ensure continuous and uninterrupted operation of the flow cytometer for several days. The device was interfaced with a FACSCalibur equipped with CellQuest software for data acquisition and analysis. Results: The set-up was tested with batch cultures of Saccharomyces cerevisiae expressing the green fluorescent protein (GFP). On-line cell counts showed close agreement with off-line measurements throughout the exponential growth of a yeast culture. The time course of light scattering, GFP fluorescence, and viability distributions provided a detailed description of changes occurring in growing cell cultures based on sampling approximately every 15 min for more than 40 consecutive hours. Therefore, the device could be used to obtain descriptions of the dynamic behavior of cell populations with no user intervention required for several days. Conclusions: The system significantly expanded the utility of flow cytometry by eliminating cumbersome and time-consuming steps that make the application of flow cytometry impractical in certain situations. It is anticipated that the described set-up will find utility in biotechnology applications such as monitoring of cell cultures, screening of biologically active compounds, and in functional genomics efforts for phenotypic characterizations of cells.

Original languageEnglish (US)
Pages (from-to)87-96
Number of pages10
JournalCytometry Part A
Volume51
Issue number2
DOIs
StatePublished - Feb 2003

Keywords

  • Automation
  • Bioreactor monitoring
  • Flow cytometry
  • Flow injection analysis
  • On-line staining
  • Population dynamics
  • Sample handling

Fingerprint

Dive into the research topics of 'Automated Flow Cytometry for Acquisition of Time-Dependent Population Data'. Together they form a unique fingerprint.

Cite this