Connections between precast elements - Failure within connection region

Catherine Wolfgram French, Michael Hafner, Viswanath Jayashankar

Research output: Contribution to journalArticlepeer-review

36 Scopus citations

Abstract

This paper presents the test results of three moment-resisting connections between precast beam-column elements designed for regions of moderate to high seismicity. The specimens are subjected to cyclic lateral load reversals that are progressively amplified until the structures are taken to inter-story drifts (ratio of lateral story displacement to story height) exceeding 4%. Two of the test specimens represent exterior connections (BME, BMF), and the third represents an interior connection (BMG). The connections include: BME—bolted, BMF—threaded rebar with ordinary couplers, and BMG—threaded rebar with tapered-threaded couplers. The plastic hinge is forced to develop within the connection region in all three specimens. The specimens exibit ductility and energy dissipation characteristics similar to those of ordinary reinforced concrete elements, as the connection regions are designed to emulate ordinary reinforced concrete in a precast system. The threaded rebar connections with tapered-threaded splices represent the most favorable solution in terms of performance, fabrication, and economy.

Original languageEnglish (US)
Pages (from-to)1371-1391
Number of pages21
JournalJournal of Structural Engineering (United States)
Volume115
Issue number12
DOIs
StatePublished - Dec 1989

Fingerprint

Dive into the research topics of 'Connections between precast elements - Failure within connection region'. Together they form a unique fingerprint.

Cite this