Abstract
The purpose of the present work was to measure the bond strength of five composite resins (two microfilled and three conventional) to human etched enamel and to correlate the findings with previously published results on the tensile strength of the same resins. The two microfilled composites showed a significantly lower bond strength than the three conventional products. The coefficient of correlation between tensile and bond strength was 0.74.
Original language | English (US) |
---|---|
Pages (from-to) | 348-351 |
Number of pages | 4 |
Journal | Scandinavian Journal of Dental Research |
Volume | 88 |
Issue number | 4 |
DOIs | |
State | Published - Aug 1980 |