External assessment of the EUROMACS right-sided heart failure risk score

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

The EUROMACS Right-Sided Heart Failure Risk Score was developed to predict right ventricular failure (RVF) after left ventricular assist device (LVAD) placement. The predictive ability of the EUROMACS score has not been tested in other cohorts. We performed a single center analysis of a continuous-flow (CF) LVAD cohort (n = 254) where we calculated EUROMACS risk scores and assessed for right ventricular heart failure after LVAD implantation. Thirty-nine percent of patients (100/254) had post-operative RVF, of which 9% (23/254) required prolonged inotropic support and 5% (12/254) required RVAD placement. For patients who developed RVF after LVAD implantation, there was a 45% increase in the hazards of death on LVAD support (HR 1.45, 95% CI 0.98–2.2, p = 0.066). Two variables in the EUROMACS score (Hemoglobin and Right Atrial Pressure to Pulmonary Capillary Wedge Pressure ratio) were not predictive of RVF in our cohort. Overall, the EUROMACS score had poor external discrimination in our cohort with area under the curve of 58% (95% CI 52–66%). Further work is necessary to enhance our ability to predict RVF after LVAD implantation.

Original languageEnglish (US)
Article number16064
JournalScientific reports
Volume11
Issue number1
DOIs
StatePublished - Dec 2021

Bibliographical note

Publisher Copyright:
© 2021, The Author(s).

Fingerprint

Dive into the research topics of 'External assessment of the EUROMACS right-sided heart failure risk score'. Together they form a unique fingerprint.

Cite this