TY - JOUR
T1 - Glass and polymeric membrane electrodes for the measurement of pH in milk and cheese
AU - Upreti, Praveen
AU - Metzger, Lloyd E.
AU - Bühlmann, Philippe
PY - 2004/5/10
Y1 - 2004/5/10
N2 - While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70% have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.
AB - While there is a considerable interest in the food industry in determining various analytes using ion-selective electrodes (ISEs), only few reports describe their use for direct measurements in food. In this study, the suitability of glass electrodes and ionophore-based solvent polymeric ISEs for the determination of pH in Process cheese, Cheddar cheese and milk was investigated. The liquid junction potential between a 3M KCl bridge electrolyte and diluted as well as undiluted Process cheese was found to be negligible. Reference electrodes with ceramic plug and sleeve-type junctions performed well, although precautions needed to be taken to prevent plugging at the junctions. While the protein rennet casein posed no problems in pH measurements, the extraction of neutral lipophilic compounds or hydrophobic peptides into solvent polymeric membranes was evident, resulting in some loss of selectivity for monovalent cations upon exposure to cheese. However, it was found that ISEs based on tridodecylamine (R3N) as ionophore and o-nitrophenyl octyl ether (oNPOE) as plasticizer can be used to accurately measure the pH of milk and, after desensitization of the electrodes in a cheese emulsion, of diluted Process cheese. Since pH measurements with a glass electrode showed that emulsions of cheese moderately diluted to a cheese content of 70% have the same pH as undiluted cheeses, it is possible to determine the pH in cheese with ionophore-based ISEs. R3N membranes also performed well in undiluted milk.
KW - Cheese
KW - Dairy products
KW - Glass electrode
KW - Ion-selective electrode
KW - Ionophore
KW - Milk
KW - pH measurement
UR - http://www.scopus.com/inward/record.url?scp=1842684439&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1842684439&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2003.12.020
DO - 10.1016/j.talanta.2003.12.020
M3 - Article
C2 - 18969412
AN - SCOPUS:1842684439
VL - 63
SP - 139
EP - 148
JO - Talanta
JF - Talanta
SN - 0039-9140
IS - 1
ER -