Minimum entropy generation due to heat transfer and fluid friction in a parabolic trough receiver with non-uniform heat flux at different rim angles and concentration ratios

Aggrey Mwesigye, Tunde Bello-Ochende, Josua P. Meyer

Research output: Contribution to journalArticlepeer-review

69 Scopus citations

Abstract

In this paper, Monte Carlo ray-tracing and computational fluid dynamics are used to numerically investigate the minimum entropy generation due to heat transfer and fluid friction in a parabolic trough receiver. The analysis was carried out for rim angles in the range 40°-120°, concentration ratios in the range 57-143, Reynolds numbers in the range 1.02 × 104-1.36 × 106 and fluid temperatures in the range 350-650 K. Results show existence of an optimal Reynolds number at any given combination of fluid temperature, concentration ratio and rim angle for which the total entropy generation is a minimum. The total entropy generation was found to increase as the rim angle reduced, concentration ratio increased and fluid temperature reduced. The high entropy generation rates at low rim angles are mainly due to high peak temperatures in the absorber tube at these low rim angles.

Original languageEnglish (US)
Pages (from-to)606-617
Number of pages12
JournalEnergy
Volume73
DOIs
StatePublished - Aug 14 2014
Externally publishedYes

Bibliographical note

Funding Information:
The funding received from NRF , TESP , and Stellenbosch University/University of Pretoria , SANERI/SANEDI , CSIR , EEDSM Hub and NAC is duly acknowledged and appreciated.

Keywords

  • Concentration ratio
  • Entropy generation
  • Monte Carlo ray-tracing
  • Parabolic trough
  • Receiver
  • Rim angle

Fingerprint

Dive into the research topics of 'Minimum entropy generation due to heat transfer and fluid friction in a parabolic trough receiver with non-uniform heat flux at different rim angles and concentration ratios'. Together they form a unique fingerprint.

Cite this