Peripheral dose heterogeneity due to the thread effect in total marrow irradiation with helical tomotherapy

Yutaka Takahashi, Michael R. Verneris, Kathryn E. Dusenbery, Christopher T. Wilke, Guy Storme, Daniel J. Weisdorf, Susanta K. Hui

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Purpose: To report potential dose heterogeneity leading to underdosing at different skeletal sites in total marrow irradiation (TMI) with helical tomotherapy due to the thread effect and provide possible solutions to reduce this effect. Methods and Materials: Nine cases were divided into 2 groups based on patient size, defined as maximum left-to-right arm distance (mLRD): small mLRD (≤47 cm) and large mLRD (>47 cm). TMI treatment planning was conducted by varying the pitch and modulation factor while a jaw size (5 cm) was kept fixed. Ripple amplitude, defined as the peak-to-trough dose relative to the average dose due to the thread effect, and the dose-volume histogram (DVH) parameters for 9 cases with various mLRD was analyzed in different skeletal regions at off-axis (eg, bones of the arm or femur), at the central axis (eg, vertebrae), and planning target volume (PTV), defined as the entire skeleton plus 1-cm margin. Results: Average ripple amplitude for a pitch of 0.430, known as one of the magic pitches that reduce thread effect, was 9.2% at 20 cm off-axis. No significant differences in DVH parameters of PTV, vertebrae, or femur were observed between small and large mLRD groups for a pitch of ≤0.287. Conversely, in the bones of the arm, average differences in the volume receiving 95% and 107% dose (V95 and V107, respectively) between large and small mLRD groups were 4.2% (P=.016) and 16% (P=.016), respectively. Strong correlations were found between mLRD and ripple amplitude (rs=.965), mLRD and V95 (rs=-.742), and mLRD and V107 (rs=.870) of bones of the arm. Conclusions: Thread effect significantly influences DVH parameters in the bones of the arm for large mLRD patients. By implementing a favorable pitch value and adjusting arm position, peripheral dose heterogeneity could be reduced.

Original languageEnglish (US)
Pages (from-to)832-839
Number of pages8
JournalInternational Journal of Radiation Oncology Biology Physics
Volume87
Issue number4
DOIs
StatePublished - Nov 15 2013

Bibliographical note

Funding Information:
This work was supported by the National Institute of Health (grant 1R01CA154491-01 ) and The Public Health Service (PHS) Cancer Center Support (grant P30 CA77598 ).

Fingerprint

Dive into the research topics of 'Peripheral dose heterogeneity due to the thread effect in total marrow irradiation with helical tomotherapy'. Together they form a unique fingerprint.

Cite this