Polyethylene glycol-coated biocompatible surfaces

Norma A. Alcantar, Eray S. Aydil, Jacob N. Israelachvili

Research output: Contribution to journalArticlepeer-review

540 Scopus citations

Abstract

Surfaces covered with polyethylene glycol (PEG; HO-(CH2-CH2-O)11-H) have been shown to be biocompatible because PEG's properties yield nonimmnunogenicity, nonantigenicity, and protein rejection. To produce a biocompatible surface coating, we have developed a method for grafting PEG onto activated silica films. We first deposited an amorphous silica film by plasma-enhanced chemical vapor deposition from SiH4 and O2 gases, which provided the flexibility to coat diverse materials with different chemistries and shapes. The silica films were activated by exposure to water plasma, increasing the number of silanol groups (SiOH) on their surface. The surface silanol groups were then chemically reacted with the hydroxyl end of PEG to form an ester bond, Si-O-C, and to cover the surface with PEG. The surface reactions were monitored using attenuated total reflection Fourier transform infrared spectroscopy. The vibrational absorption bands of the C-O and -CH2 bonds increased with time and saturated, indicating that PEG was adsorbed to saturation coverage on the surface. Simultaneously, the Si-OH absorption band decreased, showing that the surface silanols reacted with PEG and were depleted. The PEG-covered surfaces were physically characterized by atomic force microscopy, Auger electron spectroscopy, ellipsometry, and contact angle measurements. These characterization techniques provided additional evidence for the existence of chemically bonded PEG on the surfaces. Efficacy of protein rejection on PEG-covered surfaces was studied through measurements of the fluorescence intensity of Texas red-labeled bovine serum albumin brought in contact with such surfaces in solution. Significantly less protein adsorption was observed on surfaces covered with PEG compared to uncovered surfaces. (C) 2000 John Wiley and Sons, Inc.

Original languageEnglish (US)
Pages (from-to)343-351
Number of pages9
JournalJournal of Biomedical Materials Research
Volume51
Issue number3
DOIs
StatePublished - Sep 5 2000

Keywords

  • 'biocompatible coating
  • Biocompatible Surface
  • Chemical grafting of PEG
  • Polythylene glycol
  • Silica
  • Silicon oxide

Fingerprint

Dive into the research topics of 'Polyethylene glycol-coated biocompatible surfaces'. Together they form a unique fingerprint.

Cite this