TY - JOUR
T1 - Rapid, accurate and simultaneous noninvasive assessment of right and left ventricular mass with nuclear magnetic resonance imaging using the snapshot gradient method
AU - McDonald, Kenneth M.
AU - Parrish, Todd
AU - Wennberg, Paul
AU - Stillman, Arthur E.
AU - Francis, Gary S.
AU - Cohn, Jay N.
AU - Hunter, David
PY - 1992/6
Y1 - 1992/6
N2 - Left ventricular, and possibly also right ventricular, mass is an important determinant of prognosis in cardiovascular disease. Consequently, noninvasive estimation of ventricular mass may be an important clinical investigation. The ideal technique for this purpose would be widely available and accurate, employ short study times and avoid exposure to contrast agents and radiation. Conventional nuclear magnetic resonance (NMR) imaging fulfills most of these criteria, but it is time-consuming and expensive. Moreover, its accuracy in estimating right ventricular mass has yet to be assessed. Accordingly, high speed NMR imaging using the snapshot gradient echo technique was used to assess right and left ventricular mass in 10 dogs and the results were compared with values obtained at autopsy, which ranged from 26.1 to 52.9 and 61 to 119.8 g. respectively. The mean absolute difference between the NMR imaging estimates and autopsy findings was 2 ± 1.2 g (range 0.4 to 4.2) for right ventricular mass and 4.4 ± 1.7 g (range 1.8 to 6.6) for left ventricular mass. Total NMR imaging time was ≤5 min. These data demonstrate that high speed NMR imaging can be used to accurately estimate right as well as left ventricular mass.
AB - Left ventricular, and possibly also right ventricular, mass is an important determinant of prognosis in cardiovascular disease. Consequently, noninvasive estimation of ventricular mass may be an important clinical investigation. The ideal technique for this purpose would be widely available and accurate, employ short study times and avoid exposure to contrast agents and radiation. Conventional nuclear magnetic resonance (NMR) imaging fulfills most of these criteria, but it is time-consuming and expensive. Moreover, its accuracy in estimating right ventricular mass has yet to be assessed. Accordingly, high speed NMR imaging using the snapshot gradient echo technique was used to assess right and left ventricular mass in 10 dogs and the results were compared with values obtained at autopsy, which ranged from 26.1 to 52.9 and 61 to 119.8 g. respectively. The mean absolute difference between the NMR imaging estimates and autopsy findings was 2 ± 1.2 g (range 0.4 to 4.2) for right ventricular mass and 4.4 ± 1.7 g (range 1.8 to 6.6) for left ventricular mass. Total NMR imaging time was ≤5 min. These data demonstrate that high speed NMR imaging can be used to accurately estimate right as well as left ventricular mass.
UR - http://www.scopus.com/inward/record.url?scp=0026734207&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026734207&partnerID=8YFLogxK
U2 - 10.1016/0735-1097(92)90625-W
DO - 10.1016/0735-1097(92)90625-W
M3 - Article
C2 - 1534337
AN - SCOPUS:0026734207
SN - 0735-1097
VL - 19
SP - 1601
EP - 1607
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 7
ER -