Spinal cord fMRI with MB-SWIFT for assessing epidural spinal cord stimulation in rats

Hanne Laakso, Lauri J. Lehto, Jaakko Paasonen, Raimo Salo, Antonietta Canna, Igor Lavrov, Shalom Michaeli, Olli Gröhn, Silvia Mangia

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Purpose: Electrical epidural spinal cord stimulation (SCS) is used as a treatment for chronic pain as well as to partially restore motor function after a spinal cord injury. Monitoring the spinal cord activity during SCS with fMRI could provide important and objective measures of integrative responses to treatment. Unfortunately, spinal cord fMRI is severely challenged by motion and susceptibility artifacts induced by the implanted electrode and bones. This pilot study introduces multi-band sweep imaging with Fourier transformation (MB-SWIFT) technique for spinal cord fMRI during SCS in rats. Given the close to zero acquisition delay and high bandwidth in 3 dimensions, MB-SWIFT is demonstrated to be highly tolerant to motion and susceptibility-induced artifacts and thus holds promise for fMRI during SCS. Methods: MB-SWIFT with 0.78 × 0.78 × 1.50 mm3 spatial resolution and 3-s temporal resolution was used at 9.4 Tesla in rats undergoing epidural SCS at different frequencies. Its performance was compared with spin echo EPI. The origin of the functional contrast was also explored using suppression bands. Results: MB-SWIFT was tolerant to electrode-induced artifacts and respiratory motion, leading to substantially higher fMRI sensitivity than spin echo fMRI. Clear stimulation frequency-dependent responses to SCS were detected in the rat spinal cord close to the stimulation site. The origin of MB-SWIFT fMRI signals was consistent with dominant inflow effects. Conclusion: fMRI of the rat spinal cord during SCS can be consistently achieved with MB-SWIFT, thus providing a valuable experimental framework for assessing the effects of SCS on the central nervous system.

Original languageEnglish (US)
Pages (from-to)2137-2145
Number of pages9
JournalMagnetic resonance in medicine
Volume86
Issue number4
DOIs
StatePublished - Oct 2021

Bibliographical note

Publisher Copyright:
© 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Keywords

  • MB-SWIFT
  • epidural stimulation
  • fMRI
  • rats
  • spinal cord stimulation
  • zero echo time

Fingerprint

Dive into the research topics of 'Spinal cord fMRI with MB-SWIFT for assessing epidural spinal cord stimulation in rats'. Together they form a unique fingerprint.

Cite this