The compressive strength of nonprecious versus precious ceramometal restorations with various frame designs

John C. Marker, Richard J. Goodkind, William W Gerberich

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

This study was designed as a comparative analysis of the compressive strengths of precious versus nonprecious metals with various framework designs used in clinical restorations. One hundred thirty-five statistically uniform ceramometal restorations were fabricated. The restorations were cemented to the die and then subjected to stroke-control compression forces in an Instron loading machine. Simulated clinical failure was recorded by the Instron load cell recorder in pounds of load.

Original languageEnglish (US)
Pages (from-to)560-567
Number of pages8
JournalThe Journal of Prosthetic Dentistry
Volume55
Issue number5
DOIs
StatePublished - May 1986

Fingerprint

Dive into the research topics of 'The compressive strength of nonprecious versus precious ceramometal restorations with various frame designs'. Together they form a unique fingerprint.