TY - JOUR
T1 - The efficacy of fluoroscopy-guided epidural blood patch in the treatment of spontaneous and iatrogenic cerebrospinal fluid leakage
AU - Özütemiz, Can
AU - Köksel, Yasemin Kocabaş
AU - Huang, Haitao
AU - Rubin, Nathan
AU - Rykken, Jeffrey B.
N1 - Publisher Copyright:
© 2018, European Society of Radiology.
PY - 2019/8/1
Y1 - 2019/8/1
N2 - Objective: To evaluate patient outcomes following fluoroscopy-guided epidural blood patch (FGEBP), factors affecting the outcome, and to identify the rate of fluoroscopy-guided lumbar punctures (FGLP) requiring FGEBP. Methods: All FGLPs and FGEBPs between January 2014 and May 2017 were retrospectively evaluated. Information regarding patient characteristics, details of previous dural puncture (DP), details of the FGEBP, and FGEBP outcome were recorded. The outcome was classified into three categories as “complete response”, “partial response”, and “no response”. Patients with “complete response” were compared to the combined group of “no response” and “partial response”, classified as “incomplete response”. Two-sample/Fisher’s exact (continued/categorical variables) tests were used (p < 0.05). Results: Sity-seven FGEBPs were performed in 63 patients (female/male, 36/27; mean age/BMI 38/28.2). Fifty-nine were referred following DP; 31 were performed by radiologists. The rate of FGLPs requiring FGEBP was 1.78% within 3.5 years. The mean DP-FGEBP interval was 4.8 days. “Complete response” was achieved in 56 (84.8%), “no response” was found following 4 (6%) procedures. Average applied blood volume was 16 cc (5–30 cc). No difference was found between “complete response” and “incomplete response” groups regarding age, sex, BMI, DP performer, DP level, DP fluoroscopy time, DP needle caliber/type, FGEBP level, FGEBP needle caliber/type, FGEBP fluoroscopy time, FGEBP performer, and applied blood volume (p > 0.05). Despite approaching significance, no statistically significant difference was found regarding the presence of previous DP (p = 0.06). Conclusions: The efficacy of FGEBP is high in a group of patients referred to radiology for treatment of CSF leakage with complete response in 84.8% of patients. Key Points: • Fluoroscopy-guided epidural blood patch completely resolved symptoms in 85% of post-dural puncture headaches. • The success approaches 95% when including the patients with partial resolution of symptoms. • Epidural blood patch rate is found 1.8% following 1703 fluoroscopy-guided lumbar punctures.
AB - Objective: To evaluate patient outcomes following fluoroscopy-guided epidural blood patch (FGEBP), factors affecting the outcome, and to identify the rate of fluoroscopy-guided lumbar punctures (FGLP) requiring FGEBP. Methods: All FGLPs and FGEBPs between January 2014 and May 2017 were retrospectively evaluated. Information regarding patient characteristics, details of previous dural puncture (DP), details of the FGEBP, and FGEBP outcome were recorded. The outcome was classified into three categories as “complete response”, “partial response”, and “no response”. Patients with “complete response” were compared to the combined group of “no response” and “partial response”, classified as “incomplete response”. Two-sample/Fisher’s exact (continued/categorical variables) tests were used (p < 0.05). Results: Sity-seven FGEBPs were performed in 63 patients (female/male, 36/27; mean age/BMI 38/28.2). Fifty-nine were referred following DP; 31 were performed by radiologists. The rate of FGLPs requiring FGEBP was 1.78% within 3.5 years. The mean DP-FGEBP interval was 4.8 days. “Complete response” was achieved in 56 (84.8%), “no response” was found following 4 (6%) procedures. Average applied blood volume was 16 cc (5–30 cc). No difference was found between “complete response” and “incomplete response” groups regarding age, sex, BMI, DP performer, DP level, DP fluoroscopy time, DP needle caliber/type, FGEBP level, FGEBP needle caliber/type, FGEBP fluoroscopy time, FGEBP performer, and applied blood volume (p > 0.05). Despite approaching significance, no statistically significant difference was found regarding the presence of previous DP (p = 0.06). Conclusions: The efficacy of FGEBP is high in a group of patients referred to radiology for treatment of CSF leakage with complete response in 84.8% of patients. Key Points: • Fluoroscopy-guided epidural blood patch completely resolved symptoms in 85% of post-dural puncture headaches. • The success approaches 95% when including the patients with partial resolution of symptoms. • Epidural blood patch rate is found 1.8% following 1703 fluoroscopy-guided lumbar punctures.
KW - Epidural blood patch
KW - Fluoroscopy
KW - Intracranial hypotension
KW - Lumbar puncture
KW - Post-dural puncture headache
UR - http://www.scopus.com/inward/record.url?scp=85056328191&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056328191&partnerID=8YFLogxK
U2 - 10.1007/s00330-018-5828-x
DO - 10.1007/s00330-018-5828-x
M3 - Article
C2 - 30413964
AN - SCOPUS:85056328191
SN - 0938-7994
VL - 29
SP - 4088
EP - 4095
JO - European Radiology
JF - European Radiology
IS - 8
ER -