Abstract
The upgrade of the hadron calorimeter of the CMS experiment at the CERN Large Hadron Collider is currently underway. The endcap sections will be upgraded in the winter of 2016-2017 and the barrel sections during the second LHC long shutdown in 2019. The existing photosensors will be replaced with about 16 000 new silicon photomultipliers (SiPMs), resulting in the first large installation of SiPMs in a radiation environment. All associated front-end electronics will also be upgraded. This paper discusses the motivation for the upgrade and provides a description of the new system, including the SiPMs with associated control electronics and the front-end readout cards.
Original language | English (US) |
---|---|
Article number | C01080 |
Journal | Journal of Instrumentation |
Volume | 12 |
Issue number | 1 |
DOIs | |
State | Published - Jan 26 2017 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2017 IOP Publishing Ltd and Sissa Medialab srl.
Keywords
- Calorimeters
- Front-end electronics for detector readout
- Radiation-hard electronics