Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment

David Kist, A. Jay Burns, Roth Sanner, Jeff Counters, Brian Zelickson

Research output: Contribution to journalArticlepeer-review

70 Scopus citations

Abstract

Background and Objective: The radio-frequency (RF) device is a system capable of volumetric heating of the mid to deep dermis and selective heating of the fibrous septa strands and fascia layer. Clinically, these effects promote dermal collagen production, and tightening of these deep subcutaneous structures. A new technique of using multiple low energy passes has been described which results in lower patient discomfort and fewer side effects. This technique has also been anecdotally described as giving more reproducible and reliable clinical results of tissue tightening and contouring. This study will compare ultrastructural changes in collagen between a single pass high energy versus up to five passes of a multiple pass lower energy treatment. Study Design/Materials and Methods: Three subjects were consented and treated in the preauricular region with the RF device using single or multiple passes (three or five) in the same 1.5 cm2 treatment area with a slight delay between passes to allow tissue cooling. Biopsies from each treatment region and a control biopsy were taken immediately, 24 hours or 6 months post treatment for electron microscopic examination of the 0-1 mm and 1-2 mm levels. Sections of tissue 1 mm×1 mm×80 nm were examined with an RCA EMU-4 Transmission Electron Microscope. Twenty sections from 6 blocks from each 1 mm depth were examined by 2 blinded observers. The morphology and degree of collagen change in relation to area examined was compared to the control tissue, and estimated using a quantitative scale. Results: Ultrastructural examination of tissue showed that an increased amount of collagen fibril changes with increasing passes at energies of 97 J (three passes) and 122 J (five passes), respectively. The changes seen after five multiple passes were similar to those detected after much more painful single pass high-energy treatments. Conclusions: This ultrastructural study shows changes in collagen fibril morphology with an increased effect demonstrated at greater depths of the skin with multiple low-fluence passes and at lesser depths with single pass higher fluence settings. Findings suggest that similar collagen fibril alteration can occur with multiple pass low-energy treatments and single pulse high-energy treatments. The lower fluence multiple pass approach is associated with less patient discomfort, less side effects, and more consistent clinical results.

Original languageEnglish (US)
Pages (from-to)150-154
Number of pages5
JournalLasers in Surgery and Medicine
Volume38
Issue number2
DOIs
StatePublished - Feb 1 2006

Keywords

  • Collagen
  • Laser tissue interaction
  • Radiofrequency
  • Transmission electron microscopy

Fingerprint

Dive into the research topics of 'Ultrastructural evaluation of multiple pass low energy versus single pass high energy radio-frequency treatment'. Together they form a unique fingerprint.

Cite this