Use of carotid and axillary artery approach for stenting the patent ductus arteriosus in infants with ductal-dependent pulmonary blood flow: A multicenter study from the congenital catheterization research collaborative

Holly Bauser-Heaton, Athar M. Qureshi, Bryan H. Goldstein, Andrew C. Glatz, George T. Nicholson, Jeffrey J. Meadows, John S. Depaolo, Varun Aggarwal, Courtney E. McCracken, Emad B. Mossad, Elizabeth C. Wilson, Christopher J. Petit

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Background: Carotid artery (CA) and axillary artery (AA) access are increasingly used for transcatheter stenting of the patent ductus arteriosus (PDA), although reports are limited. Methods: The Congenital Catheterization Research Collaborative (CCRC) reviewed multicenter data from infants who underwent PDA stenting via the CA or AA approach from 2008 to 2017, and compared outcomes to those of infants undergoing PDA stenting via the femoral artery (FA) approach. Post-procedure ultrasound (US) imaging was reviewed. Results: Forty-nine infants underwent PDA stenting from the CA (n = 43) or AA (n = 6) approach, compared with 55 infants who underwent PDA stenting from the FA approach. The PDA was the sole pulmonary blood flow (PBF) source in 61% of infants in the CA/AA cohort, compared with 33% of the FA cohort (p <.01). Ductal tortuosity for CA/AA cohort was Type I (straight) in 10 (20%), Type II (one turn) in 17 (35%), and Type III (multiple turns) in 22 (45%) infants and reflected a greater degree of tortuosity when compared to the FA cohort (p <.01). In 17 infants with CA/AA approach, the “flip technique” was used, and was associated with shorter procedure times for highly tortuous PDA (Type III) patients. Rates of procedural complications were similar across access sites. Most common complications were access site injury (thrombus or bleeding) and stent malposition. No complications were specifically related to the “flip technique.”. Conclusions: Use of CA and AA approach for PDA stenting was found to be more commonly employed in sole source PBF and highly tortuous PDAs. Procedural modifications such as the “flip technique” may lead to shorter procedure times. CA and AA approaches are associated with a similar burden of procedural or late complications. Post-procedural surveillance of the CA and AA is suggested, given the incidence of vascular findings on US.

Original languageEnglish (US)
Pages (from-to)726-733
Number of pages8
JournalCatheterization and Cardiovascular Interventions
Volume95
Issue number4
DOIs
StatePublished - Mar 1 2020
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2019 Wiley Periodicals, Inc.

Keywords

  • PDA stenting
  • axillary access
  • carotid access

Fingerprint

Dive into the research topics of 'Use of carotid and axillary artery approach for stenting the patent ductus arteriosus in infants with ductal-dependent pulmonary blood flow: A multicenter study from the congenital catheterization research collaborative'. Together they form a unique fingerprint.

Cite this