TY - JOUR
T1 - Validation of nonradioactive chemiluminescent immunoassay methods for the analysis of thyroxine and cortisol in blood samples obtained from dogs, cats, and horses
AU - Singh, Ashok K
AU - Jiang, Yin
AU - White, T.
AU - Spassova, D.
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1997/7
Y1 - 1997/7
N2 - The performances of a radioimmunoassay method, a chemiluminescent immunoassay method, and a chemiluminescent-enzyme immunoassay method were evaluated for the analysis of cortisol and total thyroxine in blood samples obtained from dogs, cats, horses, and humans (reference samples). The analysis of cortisol in human and animal samples exhibited good precision, linearity, and recovery. The 3 methods gave comparable values for the ACTH-induced increase and the dexamethasone-induced decrease in cortisol concentrations in animal samples. The recoveries of total thyroxine from human samples, analyzed by the 3 methods, were comparable. However, the basal total thyroxine concentrations determined by the chemiluminescent immunoassay method were 30-40% lower than those determined by the radioimmunoassay and the chemiluminescent-enzyme immunoassay methods in animal samples. In both human and animal samples, the plot of thyroxine values obtained by the radioimmunoassay method against those obtained by the chemiluminescent immunoassay method or the chemiluminescent-enzyme immunoassay method was linear. However, although the slope of the radioimmunoassay versus chemiluminescent-enzyme immunoassay curve was close to unity, the slope of the radioimmunoassay versus chemiluminescent immunoassay curve was 0.6. This result suggests that, compared with the radioimmunoassay method, the chemiluminescent immunoassay method underestimated thyroxine values in animal samples but not in human samples. Although all 3 methods yielded comparable changes in thyroxine concentrations in response to thyroid stimulating hormone, they did not yield comparable thyroxine concentrations in response to T3 suppression in dogs and cats.
AB - The performances of a radioimmunoassay method, a chemiluminescent immunoassay method, and a chemiluminescent-enzyme immunoassay method were evaluated for the analysis of cortisol and total thyroxine in blood samples obtained from dogs, cats, horses, and humans (reference samples). The analysis of cortisol in human and animal samples exhibited good precision, linearity, and recovery. The 3 methods gave comparable values for the ACTH-induced increase and the dexamethasone-induced decrease in cortisol concentrations in animal samples. The recoveries of total thyroxine from human samples, analyzed by the 3 methods, were comparable. However, the basal total thyroxine concentrations determined by the chemiluminescent immunoassay method were 30-40% lower than those determined by the radioimmunoassay and the chemiluminescent-enzyme immunoassay methods in animal samples. In both human and animal samples, the plot of thyroxine values obtained by the radioimmunoassay method against those obtained by the chemiluminescent immunoassay method or the chemiluminescent-enzyme immunoassay method was linear. However, although the slope of the radioimmunoassay versus chemiluminescent-enzyme immunoassay curve was close to unity, the slope of the radioimmunoassay versus chemiluminescent immunoassay curve was 0.6. This result suggests that, compared with the radioimmunoassay method, the chemiluminescent immunoassay method underestimated thyroxine values in animal samples but not in human samples. Although all 3 methods yielded comparable changes in thyroxine concentrations in response to thyroid stimulating hormone, they did not yield comparable thyroxine concentrations in response to T3 suppression in dogs and cats.
UR - http://www.scopus.com/inward/record.url?scp=0031182540&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031182540&partnerID=8YFLogxK
U2 - 10.1177/104063879700900307
DO - 10.1177/104063879700900307
M3 - Article
C2 - 9249165
AN - SCOPUS:0031182540
SN - 1040-6387
VL - 9
SP - 261
EP - 268
JO - Journal of Veterinary Diagnostic Investigation
JF - Journal of Veterinary Diagnostic Investigation
IS - 3
ER -