When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study

E. Mcdonald, A. A. Theologis, P. Horst, U. Kandemir, M. Pekmezci

Research output: Contribution to journalArticlepeer-review

30 Scopus citations

Abstract

Purpose: This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). Methods: An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. Results: The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18–7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. Conclusion: In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.

Original languageEnglish (US)
Pages (from-to)665-671
Number of pages7
JournalEuropean Journal of Trauma and Emergency Surgery
Volume41
Issue number6
DOIs
StatePublished - Dec 1 2015

Bibliographical note

Publisher Copyright:
© 2014, Springer-Verlag Berlin Heidelberg.

Keywords

  • Biomechanical analysis
  • External fixation
  • Internal fixation
  • Pelvic fracture

Fingerprint

Dive into the research topics of 'When do anterior external or internal fixators provide additional stability in an unstable (Tile C) pelvic fracture? A biomechanical study'. Together they form a unique fingerprint.

Cite this