Digital cellular telephone interaction with implantable cardioverter- defibrillators

Joseph G. Fetter, Veronica Ivans, David G. Benditt, Joanne Collins

Research output: Contribution to journalArticlepeer-review

73 Scopus citations

Abstract

Objectives. This study sought to determine, in vivo, whether electromagnetic interference (EMI), generated by North American Digital Communications (NADC)/Time Division Multiple Access-50-Hz (TDMA-50) mobile cellular digital telephone model AT and T 6650, disturbs normal implantable cardioverter-defibrillator (ICD) operation and to verify these observations in vitro by testing a selection of telephones representing worldwide systems. Methods. The effects of cellular phone interference on the operation of various models of market-released ICDs from a single manufacturer, Medtronic, Inc., were tested. The in vivo clinical test was undertaken in 41 patients using the AT and T 6650 digital telephone with the NADC/TDMA-50 technology. The in vitro component of the study was examined twofold: 1) antenna generated far field; and 2) analog/digital cellular telephone near field. Results. None of the ICDs tested in 41 patients were affected by oversensing of the EMI field of the cellular telephones during the in vivo study. Therefore, the binomial upper 95% confidence limit for the failure rate of 0% is 7%. The in vitro antenna-generated field testing showed that telephone modulation frequencies used in the international Global System Mobile and TDMA-50 cellular telephone technologies did not result in ICD sensing interference at the predicted electric field intensity. The in vitro near field tests were performed using both analog and digital cellular telephones in service, or in the test mode, and indicated no interaction with normal operation. However, the static magnetic field generated by the cellular telephone placed over the ICD at a distance ≤0.5 cm will activate the internal reed switch, resulting in temporary suspension of ventricular tachycardia and fibrillation detection. Conclusions. We conclude that TDMA- 50 cellular telephones did not interfere with these types of ICDs. However, we recommend that the patient not carry or place the digital cellular telephone within 15 cm (6 in.) of the ICD.

Original languageEnglish (US)
Pages (from-to)623-628
Number of pages6
JournalJournal of the American College of Cardiology
Volume31
Issue number3
DOIs
StatePublished - Mar 1998

Bibliographical note

Funding Information:
Financial support for this study was provided by the Clinical Operations Department of Medtronic, Inc.

Fingerprint

Dive into the research topics of 'Digital cellular telephone interaction with implantable cardioverter- defibrillators'. Together they form a unique fingerprint.

Cite this