The fixation tines of the Micra™ leadless pacemaker are atraumatic to the tricuspid valve

Alexander R. Mattson, Jorge D. Zhingre Sanchez, Paul A. Iaizzo

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Background: Today, there is no manufacturer-supplied retrieval tool for the Micra™ pacemaker (Medtronic, Minneapolis, MN, USA); therefore, off-the-shelf catheters have been employed for retrievals. The proximal retrieval feature of the Micra™ can be snared and the device is then retracted from the myocardium, pulling the device through the tricuspid valve. This study characterizes the potential risks of Micra™ nitinol tine engagement with the tricuspid sub-valvular apparatus. Methods: Fresh human hearts nonviable for transplant (n = 10) were obtained from our regional organ procurement agency (LifeSource, Minneapolis, MN, USA). Micra™ fixation tines were affixed to a linear force transducer. Tines were then engaged in tricuspid chordae tendineae to conduct a constant velocity tensile test. Each test was run until tines disengaged from the chordae tendineae or until they released from the valve apparatus. Subsequently, biomechanical failure properties of the valve apparatus and isolated chordae tendineae were determined using a series of uniaxial tensile tests. Results: There were no chordal ruptures observed during our Micra™ tine extraction testing. Chordal failure required 15.0 times the force of extracting a single engaged tine, and 9.0 times the force of extracting two engaged tines. The uniaxial stresses required for isolated chordal failure averaged 17.4 N/mm 2 ; failure strains exceeded 150% resting chordal length. Conclusions: The forces required to rupture tricuspid chordae tendineae significantly exceeded the forces potentially imposed on the chordae during Micra™ device retrievals. We conclude that the fixation tines of the Micra™ device are unlikely to damage the tricuspid apparatus during either implant or retrieval.

Original languageEnglish (US)
Pages (from-to)1606-1610
Number of pages5
JournalPACE - Pacing and Clinical Electrophysiology
Volume41
Issue number12
DOIs
StatePublished - Dec 2018

Bibliographical note

Publisher Copyright:
© 2018 Wiley Periodicals, Inc.

Keywords

  • Micra pacemaker
  • biomechanical failure properties
  • cardiac anatomy
  • extraction
  • retrieval
  • tricuspid valve device interactions

Fingerprint

Dive into the research topics of 'The fixation tines of the Micra™ leadless pacemaker are atraumatic to the tricuspid valve'. Together they form a unique fingerprint.

Cite this