Abstract
Background: Transient groin pain is a therapeutically challenging complication associated with transobturator sling procedures. Case: We present the case of a 37-year-old woman who presented with debilitating left groin pain and dyspareunia following placement of transobturator sling. Pelvic floor physical therapy, medications, and trigger point injections failed to provide relief. Workup included magnetic resonance imaging of the pelvis, complex cystometrics, and additional trigger point injections. Surgical removal of the complete left side of the tape including the portion imbedded in the obturator foramen was performed with a combined vaginal-transcutaneous approach. Extirpation of the mesh arm brought prompt and full resolution of the patient's symptoms. Conclusions: Surgical removal of the transobturator tape through the obturator foramen can be safely performed using a combined vaginaltranscutaneous approach.
Original language | English (US) |
---|---|
Pages (from-to) | 55-57 |
Number of pages | 3 |
Journal | Female Pelvic Medicine and Reconstructive Surgery |
Volume | 17 |
Issue number | 1 |
DOIs | |
State | Published - 2011 |
Keywords
- Dyspareunia
- Groin pain
- Mesh removal
- Midurethral sling
- Transobturator tape